The little button underneath is the overheat cut out. This could be caused by any number of problems but if you've got the manual or can get hold of one there should be some basic fault finding in there to get you started.
Re: Re: Re: Re: Re: Re: Re: Re: Re: OT - the boiler mayhem continues
Then it's disgraceful that he left without fixing it. I would either ask for your money back or get another engineer free of charge. It may not be broken down but it is a fault that you called him to fix. He has witnessed...
Re: Re: Re: Re: Re: Re: Re: OT - the boiler mayhem continues
Just out of interest did the "engineer" hear the noise or did it not do it when he was there?
Re: Re: Re: Re: Re: OT - the boiler mayhem continues
It sounds like a problem with the cold main. If it was just the hot then it could be the boiler but if it does it when the cold is tap is on or even when you are not running anything (assuming the heating isn't running) it is unlikely to be...
This may not be your boiler but as an example:
http://www.ravenheat.co.uk/pdf/RSF82/RSF82screenV3.1.pdf
He should be doing at least section 7 from 7.1 to 7.2.9. More if there are any issues.
Also, I've never heard of a reverse valve. Combi's have a check valve/non-return valve on the filling...
Re: Re: Re: OT - the boiler mayhem continues
No worries. They may try to say he did a visual inspection but that is not the same as a service. At the very least he should remove the combustion chamber cover (where the burner is, not just the boiler case) to visually check for water leaks and...
It is very unlikely to be a boiler problem if it does it when the cold tap is run since the water won't go through the boiler and the boiler won't fire up. It will most likely be pipework. Try making sure the stop valve into the house is fully open (wind it as far as it will go anti-clockwise...